TF1100-FI:
uHot-tapped installation,no pipe line flow interrupted.
uNo moving parts,no pressure drop,no maintenance.
uSpool-piece transducer for best accuracy and better long-term stability.
TF1100-FI:
uHot-tapped installation,no pipe line flow interrupted.
uNo moving parts,no pressure drop,no maintenance.
uSpool-piece transducer for best accuracy and better long-term stability.
TF1100-FI Four Channels Insertion Transit Time Ultrasonic Flowmeter works on the transit-time method. It is ok to measure all kinds of liquids in fully filled pipe.The Insertion ultrasonic transducers (sensors) is hot-tapped mounting, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Features:
uHot-tapped installation,no pipe line flow interrupted.
Transmitter:
Measurement principle |
Ultrasonic transit-time dfference correlation principle |
Flow velocity range |
0.01 to 15 m/s, bi-directional |
Reaolution |
0.25mm/s |
Repeatability |
0.2% of reading |
Accuracy |
± 0.5% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Resonse time |
0.5s |
Sensitivity |
0.003m/s |
Damping of displayed value |
0-99s(selectable by user) |
Liquid Types Supported |
both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply |
AC: 85-265V DC: 24V/500mA |
Enclosure type |
Wall-mounted |
Degree of protection |
IP66 according to EN60529 |
Operating temperature |
-10℃ to +60℃ |
Housing material |
Fiberglass |
Display |
4 line×16 English letters LCD graphic display, backlit |
Units |
User Configured (English and Metric) |
Rate |
Rate and Velocity Display |
Totalized |
gallons, ft³, barrels, lbs, liters, m³,kg |
Thermal energy |
unit GJ,KWh can be optional |
Communication |
4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),datalogger |
Security |
Keypad lockout, system lockout |
Size |
244*196*144mm |
Weight |
2.4kg |
Transducers:
Degree of protection |
IP67 or IP68 according to EN60529 |
Suited Liquid Temperature |
Std. Temp.: -35℃~85℃ |
High Temp.: -35℃~150℃ |
|
Pipe diameter range |
DN65-6000 |
Transducer Size |
Type S Φ58*199mm |
Material of transducer |
Stainless Steel |
Cable Length |
Std: 10m |
Temperature Sensor |
Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1% |